Misting between the panes of a VELUX window is more common than people think. Most of the time it points to a straightforward glazing fix rather than a whole new window, and it's usually easy to spot once you know what to look for.
What "Blown" Glazing Actually Means
A double-glazed unit has a perimeter seal holding the two panes together, keeping moisture out. When that seal breaks down, moisture gets in and becomes trapped where you can’t wipe it away. In some cases it can pool at the bottom of the unit. That’s what tradespeople mean by a blown unit. It’s a different issue from the normal condensation you sometimes see on the outside of the glass, which is usually down to ventilation rather than a fault with the window itself.
What Causes a Blown Unit?
Seals typically last 15 to 25 years before natural wear causes them to fail. Poor installation, harsh cleaning chemicals and extreme weather or temperature swings can all speed this up.
Signs to Look Out For
The main giveaway is a misty or cloudy haze that sits between the panes. It doesn't clear when the room warms up or when you open the window.
You might also notice a faint discolouration or a hazy patch that seems to come and go with the weather. If wiping the glass makes no difference, the moisture is trapped inside the sealed unit rather than sitting on the surface.
Why Replace the Glazing Instead of the Whole Window
A blown unit is a problem with the glass, not necessarily the frame, hinges or opening mechanism, so there's often no need to replace the entire window.
As VELUX-accredited installers, we repair existing VELUX windows, including damaged glazing, which saves the cost and disruption of a full replacement. A failed seal can also let more heat escape, and energy-efficient glazing reduces both heat loss and condensation build-up, so it's worth getting looked at sooner rather than later.
Does It Need Building Regulations Approval?
Full window replacements fall under Building Regulations for thermal performance, but replacing just the glass is genrlaly exempt. It’s still worth checking your specific situation if you’re unsure, particularly for listed buildings or conservation areas.
When to Call in a VELUX Repair Specialist
A misted window is worth having looked at before the seal failure gets worse or starts affecting the frame around it. Our team can tell you whether you need a straightforward glazing repair or something else, such as a mechanical or electrical fault.
Find out more about our VELUX repair service, or if your window is working well and just due some care, take a look at our VELUX servicing option, which includes a check of all the mechanisms, lubrication of the fittings and hinges, and new seals and ventilation filters.
Free Quotes Across Berkshire, Surrey & Hampshire
Whether it's one window or several windReair ows in your home, get in touch with The Loft Access Company to arrange a free visit and quote.
The Loft Access Company is a VELUX Certified Installer, TrustMark registered, FENSA registered, and a proud member of the Guild of Master Craftsmen.